5. Performance and Test Conditions
 
5.1 Standard Test Conditions 
Test should be conducted with new batteries within one week after shipment from our factory and 
the cells shall not be cycled more than five times before the test. Unless otherwise defined, test and 
measurement shall be done under temperature of 20±5  and relative humidity of 45~85%. If it is 
judged that the test results are not affected by such conditions, the tests may be conducted at 
temperature 15~30℃ and humidity 25~85%RH.   
5.2 Measuring Instrument or Apparatus 
5.2.1 Dimension Measuring Instrument 
The dimension measurement shall be implemented by instruments with equal or more precision 
scale of 0.01mm. 
5.2.2 Voltmeter    
Standard class specified in the national standard or more sensitive class having inner impedance 
more than 10kΩ/V.  
5.2.3 Ammeter    
Standard class specified in the national standard or more sensitive class. Total external resistance 
including ammeter and wire is less than 0.01Ω.. 
5.2.4 Impedance Meter 
Impedance shall be measured by a sinusoidal alternating current method (1 kHz LCR meter). 
5.3 Standard Charge\Discharge 
  5.3.1 Standard Charge :Test procedure and its criteria are referred as follows: 
0.5C
5
A = 65mA     
Charging shall consist of charging at a 0.5C
5
A constant current rate until the cell reaches 4.2V. 
The cell shall then be charged at constant voltage of 4.2V while tapering the charge current. 
Charging shall be terminated when the charging current has tapered to 0.01C
5
A. Charge time: 
Approx4.0 h. The cell shall demonstrate no permanent degradation when charged between 0 ºC 
and 45 ºC. 
5.3.2 Standard Discharge 
0.2C
5
A = 26mA   
Cells shall be discharged at a constant current of 0.2C
5
A to 3.0V @ 20℃. 
 5.4 Appearance 
        There shall be no such defect as flaw, crack, rust, leakage, which may adversely affect commercial 
value of battery. 
  5.5 Initial Performance Test    
Table 2 
Item Measuring 
Procedure 
Requirements 
(1) Open-Circuit 
 Voltage 
The open-circuit voltage shall be measured 
within 24 hours after standard charge. 
≥3.85V 
(2)  AC  
Impedance  
Resistance  
The Impedance shall be measured in an 
alternating current method (1kHz LCR meter) 
after standard charge at 20±5 .
 
≤280mΩ 
(3) Nominal 
 Capacity 
The capacity on 0.2C
5
A discharge shall be 
measured after standard charge at 20±5 .
 
Discharge Capacity 
≥130mAh 
 
5.6 Temperature Dependence of Capacity (Discharge) 
Cells shall be charged per 5.3.1. and discharged @0.2C
5
A to 3.0V. except to be discharged with