temperature per Table 3 below. Cells shall be stored for 3 hours at the test temperature prior to
discharging and then shall be discharged at the test temperature. The capacity of a cell at each
temperature shall be compared to the capacity achieved at 23 ºC and the percentage shall be
calculated. Each cell shall meet or exceed the requirements of Table 3.
Table 3
discharging and then shall be discharged at the test temperature. The capacity of a cell at each
temperature shall be compared to the capacity achieved at 23 ºC and the percentage shall be
calculated. Each cell shall meet or exceed the requirements of Table 3.
Table 3
Discharge Temperature
-20℃
0℃ 23℃ 60℃
Discharge Capacity (0.2 C
5
A)
50%
80%
100% 100%
5.7 Cycle Life and Leakage-Proof
Table 4
No. Item
Criteria
Test
Conditions
1
Cycle Life
(
(
0.5 C
5
A)
Higher than 70% of the
Initial Capacities of the
Cells
Carry out 500 cycle charging/
Discharging in the below condition.
◆
Discharging in the below condition.
◆
Charge: 0.5C
5
A cc to 4.2V;
4.2V cv to 0.05 C
5
A
◆
Discharge: 0.5 C
5
A to 3.0V
◆
Rest Time between
charge/ discharge:30min.
◆
◆
Temperature:20±5℃
2 Leakage-Proof
No leakage
(visual inspection)
After full charge, store at 60±3℃
60±10%RH for 1month.
60±10%RH for 1month.