Reference material 
 
5.3 Special functions 
 
LOGO!Soft Comfort Online Help 
266
 
Operating Instructions, 06/2014 
Output Q 
Q is set/reset, depending on the stored analog value and the offset. 
* AI1 to AI8: 0 to 10 V corresponds with 0 to 1000 (internal value). 
Parameters Threshold 1 and Threshold 2 
The two threshold parameters Threshold 1 and Threshold 2 can be provided by the actual 
value of another already-programmed function:  
●  Analog comparator: Ax - Ay 
●  Analog threshold trigger: Ax 
●  Analog amplifier: Ax 
●  Analog multiplexer: AQ 
●  Analog ramp: AQ 
●  Mathematic instruction: AQ 
●  PI controller: AQ 
●  Up/Down counter: Cnt 
For the 0BA7 and 0BA8 devices, you can additionally use the actual values of the following 
already-programmed functions: 
●  On-delay: Ta 
●  Off-delay: Ta 
●  On-/off-delay: Ta 
●  Retentive on-delay: Ta 
●  Wiping relay(pulse output): Ta 
●  Edge triggered wiping relay: Ta 
●  Asynchronous pulse generator: Ta 
●  Stairway light switch: Ta 
●  Multiple function switch: Ta 
●  Stopwatch: AQ 
●  Analog filter: AQ 
●  Average value: AQ 
●  Max/Min: AQ 
●  Threshold trigger: Fre 
You select the required function by the block number. 
The thresholds are represented by the symbol Δ on the LOGO! Base Module and in the 
timing diagram below. 
 
 
0BA4: 
Gain: Range of values: 0.00 to 10.00