COMfortel 1600/2600 - Firmware Version 1.0 - Commissioning Instructions 01 08/12
Data for Connecting a Headset
PBX
Max. power distribution of 
the total of all internal 
S
0
- and U
P0
-ports
Max. no. of COMfortel 1600 
and COMfortel 2600 without 
wall-mounted power supply
COMpact
3000
2.5 W
1
COMpact 5010 VoIP
8 W (4 W per port)
4 (2 per port)
COMpact 5020 VoIP
24 W (4 W per port)
12 (2 per port)
COMmander Basic.2 (19")
60 W (4 W per port)
30 (2 per port)
COMmander Business (19")
160 W (4 W per port)
80 (2 per port)
COMmander 6000/R
60 W (4 W per port)
30 (2 per port)
COMmander 6000 RX
160 W (4 W per port)
80 (2 per port)
Microphone power consumption
Max. 0.5 mA
Microphone sensitivity
45 dB
Loud speaker impedance
150 Ohm
Loud speaker sensitivity at 1 kHz
19.5
앧3 dBPa/V
Sound pressure limit
24 dBPa
Headset jack pin-out 
 COMfortel 1600
1
Microphone -
2
Loudspeaker -
3
Loudspeaker +
4
Microphone +
Headsetbuchse jack pin-out 
 COMfortel 2600
1
DHSG BUS_IN
2
DHSG GND
3
Microphone -
4
Loudspeaker -
5
Loudspeaker +
6
Microphone +