Datalogic PowerScan PD9500 PD9530-HPK1 数据表
产品代码
PD9530-HPK1
Enter/Exit Programming Mode
126
PowerScan™ PD9530/PBT9500/PM9500
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The length includes the bar code’s
check and data characters. The length can be set from 2 to 50 characters in
increments of two.
provides some examples for setting Length 1. See
for
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
yield two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters