Datalogic PowerScan PD9500 PD9530-HPK1 数据表
产品代码
PD9530-HPK1
Enter/Exit Programming Mode
Product Reference Guide
127
I 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for
Mode, or
the second fixed length if in
Mode. The length includes the bar
code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to
The length can be set from 2 to 50 characters. A setting of 0 specifies to
ignore this length (only one fixed length).
provides examples for setting Length 2. See
for detailed
instructions on setting this feature.
Table 9. I 2 of 5 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This
Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
yield two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L2
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters