Enter/Exit Programming Mode
130
PowerScan™ PD9530/PBT9500/PM9500
Standard 2 of 5 Check Character Transmission
This feature enables/disables transmission of an optional Standard 2 of 5 
check character.
$CS2CT00(CR)
Standard 2 of 5 Check Character Transmission = 
Don’t Send
$CS2CT01(CR)
Standard 2 of 5 Check Character Transmission = Send
DEFAULT
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the Standard 2 of 5 symbology.
Variable Length: 
For variable length decoding, a minimum and maximum 
length may be set.
Fixed Length: 
For fixed length decoding, two different lengths may be set.
DEFAULT
$CS2LC00(CR)
Standard 2 of 5 Length Control = Variable Length
$CS2LC01(CR)
Standard 2 of 5 Length Control = Fixed Length