Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
Product Reference Guide
                           131
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for 
. Length 1 is the minimum label length if in 
Variable Length
 Mode, or 
the first fixed length if in 
 Mode. Length includes the bar code’s 
check and data characters. The length can be set from 1 to 50 characters.
 provides some examples for setting Length 1. Se
 if you 
want detailed instructions on setting this feature.
Table 10. Standard 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From 
 ‘0’ and ‘1’
 ‘0’ and ‘7’
 ‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
~
CANCEL
DEFAULT
08 = Length 1 is 8 Characters