Enter/Exit Programming Mode
238
PowerScan™ PD9530/PBT9500/PM9500
Changing System Speed 
1. Link the PM9500 with a BC9xxx Base. 
2. With the PM9500, read a “Compatible Mode/Normal Mode Speed” pro-
gramming label on 
 to set “Low, Medium, or High Speed”.
3. Place the PM9500 into the BC9xxx. 
The Reader and Base will now be linked at the new programmed speed.
This feature can also be programmed using Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible mode parameter to low, 
intermediate, or high speed through Aladdin.
2. Place an unlinked PM9500 onto the BC9xxx base. 
The Reader and base will link at the new programmed speed.
Frequency Agility
In exceptionally noisy environments or in case of a high concentration of 
radio devices, Star system performance may be improved by configuring 
Frequency Agility. Frequency Agility parameters change the way the radio 
frequencies are used in a Star communication system. 
As when changing the System Speed, use the following procedure:
1. Link the PM9500 with a BC9xxx Base. 
2. With the PM9500, read one of the “Frequency Agility” programming 
labels below.
3. Place the PM9500 into the BC9xxx. 
Reader and Base will then be linked and the new frequencies handling will be 
operational.
DEFAULT
 
 
 
 
 
 
$CSTFA00
Use default fixed channel 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
$CSTFA80
Enable frequency hopping
The channel is changed automatically