Enter/Exit Programming Mode
262
PowerScan™ PD9530/PBT9500/PM9500
Quantity/Code Send Mode
This feature defines the rules that will be used to send a QTY/CODE pair: 
0.  Code is transmitted with QTY field (and its predefined format) preced-
ing CODE field (and its predefined format) 
1.  Code is transmitted with CODE field (and its predefined format) preced-
ing QTY field (and its predefined format) 
2.  Code in CODE field is sent out for the number of times defined in the 
QTY field  
$CPWEH00\r
Qty precedes Code 
DEFAULT
$CPWEH01\r
Code precedes Qty
$CPWEH02\r
Code transmitted Qty times
Quantity/Code Separator 
This feature allows the insertion of a separator between Qty/Code pairs. 
DEFAULT
$CPWQP00\r
No separator
$CPWQP
Set Qty/Code string separator
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the barcode at 
left. Next scan 1 digit from 
 (in 
the range 1-8) representing the number of characters to 
be used as separator. 
Finally, define the separator string by reading the 
desired characters from the ASCII table at the back of 
this manual, expressed in hexadecimal form. End by 
scanning the ENTER/EXIT bar code again.