References
306
PowerScan™ PD9530/PBT9500/PM9500
PM9500-Only Features
Changing System Speed in Normal Mode
1. Link the PM9500 with a BC9xxx Base. 
2. With the PM9500, read a Compatible Mode programming label on 
 to set low, intermediate, or high speed.
3. Place the PM9500 into the BC9xxx. 
The Reader and Base will now be linked at the new programmed speed.
This feature can also be programmed using Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible mode parameter to low, 
intermediate, or high speed through Aladdin.
2. Place an unlinked PM9500 onto the BC9xxx base. 
The Reader and base will link with the new programmed speed.
Bluetooth-Only Features
Bluetooth Pin Code 
This option specifies the 4-character or 16-character pin code to be used 
for authentication of the Bluetooth 
link. 
To set the pin code:
1.
Scan the 
ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode, then enable 
2.
Specify the desired pin code length (4 or 16) by scanning the appropri-
3. Determine the desired characters. For example, D254 or 
STOR12345678135M.
4. Convert the characters to hexadecimal using the
on the 
inside back cover of this manual. 
 and Scan the bar code: SET 4 CHAR PIN CODE or SET 
16-CHAR PIN CODE.
6. Scan the appropriate alphanumeric characters from the keypad in 
, representing the hexadecimal entries determined 
in the steps above. You will hear a two-beep indication after the last 
character.
If you make a mistake before the last character, scan the CANCEL bar code 
to abort and not save the entry string. You can then start again at the 
beginning.