Phoenix Contact 2900420 ELR H5-IES-SC-230AC/500AC-2 2900420 数据表

产品代码
2900420
下载
页码 56
18
4.3. Parameterization - Nominal current setting 
• Actuate the Reset button for more than 6 s in 
order to switch to the "Parameterization" 
operating mode; the green LED PWR flashes 
again. 
In the Parameterization mode, the LEDs are 
switched off after every 2 s for 0.3 s in order to 
differentiate this mode from other operating 
modes.
• Set the nominal current of the drive using the 
240° potentiometer. The nominal current is 
specified in 16 stages. The four LEDs display the 
set current. 
• Save the value by actuating the Reset button 
again (non-volatile range of the data memory). 
• Actuate the Reset button for more than 2 s (and 
less than 6 s) to display the set current for 3 s. 
 
This function is possible only if 
 
1) the device is not activated, and 
 
2) there is no defect in the device.
From a motor current of 45 A, the blocking monitoring is activated
 
(see 8.1. Trigger characteristic curve).
5. Application examples
5.1. EMERGENCY STOP
Integrating a hybrid motor starter into an EMERGENCY STOP chain is pictured in Fig. 3 (page 54). 
Here, the control voltage supply is switched off via the safety relays, as soon as the EMERGENCY STOP 
button is actuated.
Switching off the control voltage supply with a controlled motor always results in wear in 
the hybrid motor starter. 
This switch should only be used if no more than 10,000 shutdowns can be expected over the entire 
lifespan system.
If the switch-off is performed, for instance, from a "safe controller" with semiconductor outputs, the 
residual voltage must be < 5 V DC. Interruptions ≤ 1 ms are filtered. 
5.2. Safety door (EMERGENCY STOP)
In applications where the safety switch-off is a normal operating mode, such as in the case of safety door 
or two-hand applications, a circuit as per Fig. 4 (page 55) should be used.
In this application, the control current circuit is switched and not the control supply voltage. 
If the switch-off is performed, for instance, from a "safe controller" with semiconductor outputs, the 
residual voltage must be < 5 V DC. Interruptions ≤ 3 ms are filtered. 
5.3. Motor overload protection
All safety-relevant functions are realized by the hybrid motor started without any external influence. 
Special circuit technologies are not necessary.
Wiring of the load current circuit should be realized in the above examples. The connection of the module 
current supply can however be established directly to the voltage source without the PSR safety relay. 
The same is applicable for the activation.
Code
Nominal current [mA]
Variant:
PWR ERR
L
R
0.6 A
2 A
9 A 
0
0
0
0
75
180
1500
0
0
0
1
110
250
2000
0
0
1
0
145
410
2500
0
0
1
1
180
560
3000
0
1
0
0
215
710
3500
0
1
0
1
250
870
4000
0
1
1
0
285
1020
4500
0
1
1
1
320
1170
5000
1
0
0
0
355
1330
5500
1
0
0
1
390
1480
6000
1
0
1
0
425
1630
6500
1
0
1
1
460
1790
7000
1
1
0
0
495
1940
7500
1
1
0
1
530
2090
8000
1
1
1
0
565
2250
8500
1
1
1
1
600
2400
9000