Smartwares 10.001.32 用户手册
Page 35
Figure 4.6 Time Range Setup
【Time Interval】Within the scheduled time interval, if there are several occurrences, the detection
only triggers alarm in sequence;
【Alarm Output】When motion occurs, the setting will activate corresponding external devices
connected to the alarm output port;
【Delay】Indicate the extended time for which the alarm will continue after the alarm ends, ranging
from 10~300 seconds
;
【Recording Channel】Select the desired recording channel (Can be ticked). When alarm is
triggered, the system will activate the recording signal on that channel
;
Note: To perform corresponding video recording, it requires the settings in
【Record Settings】
to activate test recording in the defined time periods
【Auto Sequence】Highlighted ■
■
■
■ indicates it is selected. When alarm signal is present, the
selected channel will start single-screen auto sequence preview. The interval for auto
sequence is defined in
【System Settings】>【Auto Sequence Settings】;
【Snapshot】Select the desired recording channel (Can be ticked). When alarm is triggered, the
system will activate a snapshot signal on that channel
;
Note: To perform the corresponding snapshooting, it requires the settings in
【Record Settings】
to activate test recording in the defined time periods
【PTZ Linkage】When alarm occurs, the PTZ on the defined channel will coordinate the action. Set
it as shown in Figure 4.7
;
Note: To coordinate PTZ, you need to set parameters for preset points, point-to-point patrol,
and auto sequence in
【Quick Launch】>【PTZ Control】