Brennenstuhl 1241000300 数据表

下载
页码 12
Introduction
Please read these instructions in their entirety before commen-
cing with the installation. Save these instructions and pass them
on to third parties, as appropriate.
Scope of Delivery
Please check immediately after unpacking the goods whether the
shipment is complete and the merchandise is in good condition.
1 automatic cable reel
2 wall anchors
Specifications
General
Operating voltage
230 V / 50 Hz
Child protection
yes
Overheating protection
yes
Pivotable
180º
Model KT A92 V315 DE
Total cable length
9 + 2 metres
Cable type
H05VV-F3G1,5
Max. load:
Coiled
1,400 Watt
Uncoiled
2,000 Watt
Protection type
IP20
The automatic cable reel is suitable for use in dry interior rooms.
Model KT A92 N315 IP44 DE / BE
Total cable length
9 + 2 metres
Model KT A162 N315 IP44 DE
Total cable length
16 + 2 metres
Model KT A92 N315 IP44 DE / BE
Model KT A162 N315 IP44 DE
Cable type
H07RN-F3G1,5
Max. load:
Coiled
1,000 Watt
Uncoiled
3,500 Watt
Protection type
IP44
The automatic cable reel is suitable for permanent outdoor use.
Mounting
– The automatic cable reel features a holder with two mounting
holes.
– Using the holder's mounting holes as guides, mark the location
of the bore-holes for mounting.
– Drill the required holes.
– Use suitable mounting material (M 6 screws) to attach the
 automatic cable reel.
Operation
– Connect the plug of the automatic cable reel to a mains socket.
– Connect an appliance to the automatic cable reel's safety
 socket.
– The automatic cable reel features a cable management system
with automatic rewind capability.
– The cable snaps in place after each half turn, and automatic
 rewinding stops.
– To coil up the cable, pull the cable until it releases from the  locked
position (makes no sound), then slowly let the cable rewind.
– IMPORTANT: The tractive forces are very high. Avoid uncontrol-
led rewinding of the cable. Hold the cable end and slowly guide
it towards the automatic cable reel.
Overheating Protection
– The LED on the automatic cable reel lights up red to show that
the overheating protection is working.
– The LED goes out when the overheating protection is triggered
(56+/-5 ºC).
– In that case the power plug must be disconnected.
– After a short cooling-off period, you can start using the
 automatic cable reel again by pressing the red button.
Safety Notes
– All installation and repair work must be carried out by a
 qualified technician.
– Make sure when changing lines that the shortest possible path
is used to connect the L/N conductors to the clamps and that
the earth wire is connected to the marked clamp and is at least
12 mm longer than the other L/N conductors.
– If necessary, the overheating protection must be replaced with
a new component with the same rated values.
– The plugs must be disconnected from the outlet before the
cable is coiled or uncoiled.
– Do not exceed the maximum load (see Specifications).
Maintenance / Cleaning
Important: Make sure the automatic cable reel is de-energised for
cleaning. To de-energise the cable reel, disconnect the safety plug
from the mains socket.
This product does not require servicing.
To clean the exterior of the automatic cable reel simply wipe with
a clean, dry cloth. Make sure the automatic cable reel does not get
wet.
Dispose of electrical devices in an environmentally
 responsible manner!
Do not dispose of electrical devices with household
 rubbish!
In accordance with Directive 2012/19/EC on waste electrical
and electronic equipment, used electrical equipment must be
 collected separately and reused or recycled in an environmentally
responsible manner.
Please contact your local authorities for available disposal options
for your worn-out device.
Addresses
Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1-3 · 72074 Tübingen · Germany
H. Brennenstuhl S.A.S. · F-67460 Souffelweyersheim
lectra-t ag · Blegistrasse 13 · CH-6340 Baar
www.brennenstuhl.com
Instructions for use Automatic Cable Reel
3
042213 Automatik-Kabeltrommeln  30.04.13  14:12  Seite 3