Graco HUSKY 312877C 用户手册
Installation
312877C
9
Fluid Supply Line
1. Use grounded fluid supply lines (G). See
2. If the inlet fluid pressure to the pump is
more than 25% of the outlet working pres-
sure, the ball check valves will not close
fast enough, resulting in inefficient pump
operation.
sure, the ball check valves will not close
fast enough, resulting in inefficient pump
operation.
3. At inlet fluid pressures greater than 15 psi
(0.1 MPa, 1 bar), diaphragm life will be
shortened.
shortened.
4. For maximum suction lift (wet and dry), see
Fluid Outlet Line
See F
1. Use grounded fluid hoses (L). See
2. Install a fluid drain valve (J) near the fluid
outlet.
3. Install a shutoff valve (K) in the fluid outlet
line.
F
IG
. 2. Vent exhaust air
Key:
A
A
Air supply line
B
Bleed-type master air valve
C
Air regulator
D
Air inlet
E
Master air valve (for accessories)
F
Air line filter
T
Muffler
U
Grounded air exhaust hose
V
Container for remote air exhaust
A
B
C
D
E
F
T
U
V
ti14219a