Whirlpool WED9151YW 用户手册

下载
页码 20
9
POWER SUPPLY 
CORD CONNECTION
Power supply cord strain relief:
1. 
Attach power supply cord strain relief
D
C
B
A
Remove the screws from a 3/4" (19 mm) UL listed strain relief 
(UL marking on strain relief). Put the tabs of the two clamp 
sections (C) into the hole below the terminal block opening 
(B) so that one tab is pointing up (A) and the other is pointing 
down (D), and hold in place. Tighten strain relief screws just 
enough to hold the two clamp sections (C) together.
2. 
Attach power supply cord  
to strain relief
Put power supply cord through the strain relief. Be sure that 
the wire insulation on the power supply cord is inside the 
strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position. Do not further 
tighten strain relief screws at this point.
4-WIRE POWER SUPPLY 
CORD CONNECTION
4-wire receptacle (NEMA 
type 14-30R)
4-prong plug
Spade terminals with 
upturned ends
Ring terminals
IMPORTANT: A 4-wire connection is required for moble homes 
and where local codes do not permit the use of 3-wire connections.
1. 
Prepare to connect neutral ground 
wire and neutral wire
E
B
A
2. 
Connect neutral ground wire and  
neutral wire
C
E
B
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Connect neutral ground wire (E) and neutral wire (white or 
center) (C) of power supply cord under center terminal block 
screw (B). Tighten screw.
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to “4-Wire Power Supply Cord  
Connection” on this page.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to “3-Wire Power Supply Cord  
Connection” on page 10.
If your outlet looks like this:
If your outlet looks like this: