WhisperKool XLT SERIES XLT 3000 用户手册

下载
页码 36
Page 11
XLT 020111
Carefully remove your WhisperKOOL unit from the box. Do not destroy your packing material, as it 
provides the only safe means of transporting the unit. Units weigh 65–100 pounds and are cumbersome 
for one person to carry. We recommend that you get someone else to help you during the installation 
process.
Testing Unit
Place  the WhisperKOOL  system  on  a  tabletop  to 
prepare it for installation and testing. Locate the 
by-pass  plug  and  insert  it  into  the  thermostat 
plug,  located  on  the  front  of  the  WhisperKOOL 
System. Next, plug the system into a live electrical 
outlet  and  turn  the  unit  on.  The  system  should 
begin cooling. The system may take up to 10 to 15 
minutes before running cool. Once the operation 
has been tested, turn the unit off, unplug the unit 
from  the  electrical  outlet,  remove  the  by-pass 
plug, and install thermostat.
Note:    If  the  system  does  not  seem  to  be 
running cool after 15 minutes, please refer to 
the Troubleshooting Guide on page 19.
Before installation, use the by-pass 
test plug to test the unit.
Attach precut foam tape to the unit’s flange.
Foam Tape
Adhesive Covering
Flange
Test Plug
Applying Insulation Tape
Locate  the  four  precut  pieces  of  black  foam  tape 
included with your system. There should be two larger 
pieces  and  two  smaller  pieces.  Start  with  the  large 
pieces.  Peel  back  the  white-paper  adhesive  covering, 
and  attach  the  large  pieces  to  the  sides  of  the  unit 
flange. Then follow with the two smaller pieces on the 
top and bottom. This foam creates a tight seal between 
the unit’s flange and the wall (see illustration).
Note:  Failure  to  install  foam  strips  may  void  the 
warranty.
Liquid Measuring Thermostat System
To assure a consistent temperature, place bottle probe 
approximately 3 feet away from the air output and not 
in the flow of the air.
.