WhisperKool XLT SERIES XLT 3000 用户手册

下载
页码 36
Page 13
XLT 020111
Drain line
T-Fitting
WRONG: Drainline is under water.
USING THE WHISPERKOOL SYSTEM
®
FRONT
REAR
OFF
POWER
Location of control switches
Switches
Power Switch
XLT  units,  built  after  June  2007,    come  equipped  with  a 
3-position ON/OFF power switch. The upper position activates 
power from the cellar side outlet located on the side of unit. The 
bottom position activates power from the rear position outlet. 
The center position is OFF and is simply used when the owner 
does not need to utilize the equipment.
NOTE; (It will take five minutes before the unit begins to 
operate once the switch is placed in the “On” position. This 
is due to the designed safety delay in the PDT thermostat.)
Condensate Evaporator Switch
The Condensate Evaporator is a heating element that automatically evaporates excess condensate that 
accumulates  in  the  cooling  system  as  a  by-product  of  refrigeration.  Only  the  WhisperKOOL  units  are 
equipped with sophisticated heating elements that automatically sense the presence of water and work 
continually  until  the  water  is  gone.  Setting  the  Condensate  Evaporator  to  the “On”  setting  causes  the 
heating element and the right exhaust fan to stay on continuously to prevent excess condensation from 
building up in the unit.
Drain Line
All  units  come  with  a  drain  line  for  additional 
removal of excessive condensate. This is a back up 
system  to  the  Condensate  Evaporator.  It  is 
mandatory  to  install  the  drain  line  attachment. 
During operation, the cooling unit will strip excess 
water from the air in order to maintain the proper 
level of humidity within the cellar. The Condensate 
Evaporator  will  heat  and  dissipate  the  excess 
moisture through the rear of the unit. However in 
extreme  humidity,  additional  condensate  will  be 
created.  Conversely  the  high  humidity  air  has  less 
capacity to absorb additional moisture through the 
exhaust of the unit. Thus the drain line will prevent 
overflow and leaking by allowing for discharge of 
the  additional  condensate. WhisperKOOL  carries  a 
condensate  pump  kit,  which  allows  the  excess 
condensate to be pumped up to 20 ft. away from 
the unit. See page 29 for details.
Failure to install the drain line voids warranty. 
To  prevent  mold  from  growing,  allow  the 
drainline to hang above the water line.