TROUBLESHOOTING GUIDE
Try this first!
Clean off any accumulated dust, lint, or other debris from the front and rear intake grills. This will 
restrict the airflow and may affect the unit’s ability to function properly. Periodically cleaning the 
unit’s vents will help assure maximum cooling efficiency.
Before contacting Customer Service regarding a performance issue with your cooling unit (does not 
cool, leaks, ices up, etc.), please review the following troubleshooting information and complete the 
Troubleshooting Checklist found on page 24. It is designed to help you identify the issue yourself and 
provide appropriate advice to remedy the issue or problem. 
If you are unable to identify or solve the issue after completing and following these steps, fax a com-
pleted Troubleshooting Checklist to WhisperKOOL Customer Service at 1(209) 466-9606. The checklist 
will provide Customer Service with background information on your cooling unit installation and wine 
cellar to better assist you in resolving the issue. Be sure to include accurate contact information.
Airflow
Proper airflow is critical to the performance of the WhisperKOOL unit. Any obstruction to the intake and 
exhaust  ports  on  either  side  of  the  unit  will  compromise  the  unit’s  ability  to  cool.  Make  sure  the 
WhisperKOOL
 
unit fan vents are clear. Check the front and rear intake vents for any possible obstruction. 
There should be a minimum clearance of three feet directly in front of the intake and exhaust vents.
Problem 
Likely Cause 
Remedy
The unit does not  
Inadequate door seal 
See “Door Seal” section on pg. 20
cool the room  
Improperly mounted unit 
See “Unit Mounting” section on pg. 21
 
Unit has inadequate ventilation 
See “Airflow” and “Ventilation” sections on pg. 19 & 20
 
Foam strips are not attached 
See page 11 (in the "Installation" section)
 
Water leaking  
Condensate Evaporator is not 
See Water Leaking, Rear in the “Condensation”
from the rear 
   properly set for local climate 
section on pg. 22
 
Drain line is not attached 
See “Drain line” section on pg. 13
Unit is icing up 
Poor Air Flow 
See “Thermostat” section on pg. 21 
 
Unit is low on refrigerant 
See “Icing Up” section on pg. 22
 
Probe not in bottle 
See “Liquid Measuring Thermosat” section on pg. 14
Unit isn’t running  
Problem with local electrical 
See “Power Requirements” section on pg. 22
or makes intermittent  circuit
clicking noises