WhisperKool XLT SERIES XLT 3000 用户手册

下载
页码 36
Page 21
XLT 020111
Unit Mounting
Mounting  the  unit  in  the  cellar  has  a  significant 
impact on the unit’s ability to cool the air in the room. 
A law of nature states that warm air rises while cool air 
falls. The unit must be mounted high in the room in 
order to capture the warm air and replace with cool 
air.    If  the  unit  is  mounted  low  in  the  cellar,  it  has  a 
tendency to circulate the cool air at the bottom of the 
cellar but has no ability to draw the warm air from the 
higher  space  in  the  cellar.  This  will  result  in  an 
inconsistent temperature range.
Thermostat
If  the WhisperKOOL  unit  is  not  cooling  the  room,  it 
might be due to a faulty thermostat. Use the following 
procedure  to  test  the  thermostat.  Each  unit  has  a 
bypass plug included with the instruction guide. The 
bypass plug is used to help troubleshoot the cabinet 
when  it  is  not  cooling  correctly.  It  allows  you  to 
determine  whether  the  problem  lies  within  the 
thermostat  or  the  cooling  unit  itself. The  process  of 
using this plug is as follows:
1.)  Unplug the WhisperKOOL
 
unit.
2.)  The  PDT  thermostat  is  attached  to  the  front  of  the 
WhisperKOOL unit with two screws, one at each end 
of the thermostat. Remove the screws and detach the 
PDT.
3.)  Unplug the PDT from the main unit, and plug in the 
by-pass  plug.  The  by-pass  plug  allows  you  run  the 
WhisperKOOL
 
without  having  the  thermostat 
installed.
4.)  Plug  the  WhisperKOOL  unit  back  in.  The  unit  will 
begin running and cooling immediately. Let the unit 
run for 24 hours.
5.)  After  24  hours,  use  an  accurate  thermometer 
(preferably  a  high-quality  digital  thermometer)  to 
measure  the  temperature  of  air  coming  out  of  the 
WhisperKOOL unit’s front fans. If it is cooling the room, 
then the problem may lie with the thermostat.
If  the WhisperKOOL
 
unit  cools  the  room  without  the  PDT  installed,  then  the  thermostat  should  be 
replaced. The by-pass plug will allow the WhisperKOOL unit to continue to function, but it will not be 
able to monitor or maintain the correct temperature automatically without the thermostat.
The unit should be ran for 24hr. If you continue to run the WhisperKOOL you will need to turn off the 
WhisperKOOL unit periodically to keep it from icing up. We recommend cycling the unit on and off 
every eight hours if possible or as needed. It is recommended to run during the day and turn off at 
night.
For replacement of the PDT, please contact Customer Service.  See Warranty Service on page 30.
Mount WhisperKOOL high in the room.