Electrical wiring must conform with the latest revisions of 
the National Electrical Code, ANSI/NFPA No. 70, and/or 
local authority having jurisdiction.
1. 
When an external electrical source is utilized, the 
boiler, when installed, MUST BE electrically grounded 
in accordance with these requirements.
2. 
Install a fused disconnect switch between boiler and 
meter at a convenient location.
3. 
When the boiler is equipped with self-energized 
controls, no outside source of electric power shall be 
connected to the circuit of this system. (See "Steam 
Wiring" on next page.)
Thermostat Installation
1. 
Thermostat should be installed on inside wall about 
four feet above floor.
2. 
NEVER install thermostat on outside wall.
3. 
Do not install thermostat where it will be affected by 
drafts, hot or cold pipes, sunlight, lighting fixtures, 
television, fireplaces, or chimneys.
4. 
Check thermostat operation by raising and lowering 
thermostat as required to start and stop burner.
5. 
Instructions for final adjustment of thermostat 
are packaged with thermostat (adjusting heating 
anticipator, calibration, etc.).
ELECTRICAL WIRING
WARNING
Electrical shock hazard.  Turn OFF electrical power 
supply at service panel before making electrical  
connections.  Failure to do so could result in death 
or serious injury.
!