Universal Security Instruments MICN109 数据表

下载
页码 3
 
Page 2 of 3 
 
AUDIBLE & VISUAL SIGNALS 
 
CONDITION / 
RECOMMENDATION 
 
 
HORN 
POWER 
GREEN LED 
SMOKE 
RED LED 
GAS 
BLUE LED 
CO 
RED LED 
1 beep, 
2 second pause, 
repeat 
Turns Off when 
the 1 beep 
starts 
Off 
Off 
Off 
Condition: Non-originating GAS Alarm. 
Recommendation: An interconnected GAS 
alarm has sensed GAS, causing all 
interconnected units to sound. If hazard is 
identified, take all precautions if an alarm 
sounds by calling an Emergency Service and 
getting out of the home. 
Horn sounds when 
no hazard is 
present 
Turns Off when 
the beeps start 
Off or Blinks 
On approx. 
once every 
second 
Off or Blinks 
On in sync 
with the 1 
beep 
Off or Blinks 
On in sync 
with 4 beeps 
Condition: Nuisance Alarm. 
Recommendation: If there is no hazard 
present, verify the alarm is mounted in the 
correct location (see User’s Manual). Reset 
alarm as instructed below. 
3 beeps, 
2 second pause, 
repeat 
Turns Off when 
the 3 beeps 
start 
Blinks On 
approx. once 
every second 
Off 
Off 
Condition: Smoke alarm when cause of 
alarm is known and poses no threat. 
Recommendation: The smoke alarm Silence 
Feature can be activated by pressing and 
releasing the Test/Silence button on the 
initiating alarm while in alarm condition. 
Silence mode will last for approx. 8-12 
minutes (with the red LED blinking on approx. 
every 10 seconds). 
4 beeps, 
5 second pause, 
repeat 
Turns Off when 
the 4 beeps 
start 
Off 
Off 
Blinks On in 
sync with 4 
beeps 
Condition: CO alarm when cause of alarm is 
known and poses no threat. 
Recommendation: The CO alarm Silence 
Feature can be activated by pressing and 
releasing the Test/CO Silence button on the 
initiating alarm while in alarm condition. The 
alarm will remain silent for approx. 5 minutes 
(with the red LED blinking on approx. every 
10 seconds), depending on the level of CO 
detected. If CO levels drop below alarm 
levels, the alarm will remain silent and return 
to normal operation. If CO levels remain 
constant or increase, this indicates a 
potentially dangerous situation and the horn 
will sound again. Ventilate area. 
Silent (alarmed 
previously) 
On and Blinks 
Off approx. 
every 20 
seconds 
Off or Blinks 
On approx. 
every 5 
seconds until 
reset 
Off or Blinks 
On approx. 
every 5 
seconds until 
reset 
Off or Blinks 
On approx. 
every 5 
seconds 
until reset 
Condition: Previous alarm condition at 
unidentified source. 
Recommendation: QUICK FIND® Alarm 
Origination - In an interconnected system, it is 
difficult to determine which alarm initiated the 
alarms to sound. The QUICK FIND® feature 
will immediately allow you to locate the 
originating alarm (once the alarms have 
stopped sounding). To initiate QUICK FIND®, 
press the Test/Silence button on any alarm. 
After releasing the button, the test sequence 
will sound and then stop. Then, the originating 
alarm will continue to sound for approx. 50 
seconds. In a non-interconnected installation, 
it is necessary to test each alarm to determine 
the originating alarm. Reset the originating 
alarm. 
Horn has stopped 
sounding 
On and Blinks 
Off approx. 
every 20 
seconds 
Off and Blinks 
On approx. 
every 5 
seconds until 
reset 
Off 
Off 
Condition: Latching smoke LED indicator. 
The alarm has previously detected smoke 
and had alarmed. 
Recommendation: Follow the reset 
instructions to remove the latching LED. 
Horn has stopped 
sounding 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off 
Off and Blinks 
On approx. 
every 5 
seconds until 
reset 
Condition:  Latching  CO  LED  indicator.  The 
alarm  has  previously  detected  CO  and  had 
alarmed. 
Recommendation: Follow the reset 
instructions to remove the latching LED.