AUDIBLE & VISUAL SIGNALS 
 
CONDITION / 
RECOMMENDATION 
 
 
HORN 
POWER 
GREEN LED 
SMOKE 
RED LED 
GAS 
BLUE LED 
CO 
RED LED 
Horn has stopped 
sounding 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off and Blinks 
On approx. 
every 5 
seconds until 
reset 
Off  
Condition: Latching GAS LED indicator. The 
alarm has previously detected GAS and had 
alarmed. 
Recommendation: Follow the reset 
instructions to remove the latching LED. 
Silent (alarmed 
previously) 
On and Blinks 
Off approx. 
every 20 
seconds 
Off or Blinks 
On approx. 
every 5 
seconds until 
reset 
Off or Blinks 
On approx. 
every 5 
seconds until 
reset 
Off or Blinks 
On approx. 
every 5 
seconds until 
reset 
Condition: Alarm needs to be reset due to 
abnormal operation/previous alarms. 
Recommendation: To reset the alarm, hold 
the Test/Silence button for 10 seconds or until 
the blue LED turns on. This will clear the 
alarm origination and latching LEDs. Reset 
after each alarm event. 
1 Chirp approx. 
every 40 seconds 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off 
Off 
Condition: Low battery. 
Recommendation: Check to make sure a 
battery is present in the drawer, the battery 
activation pull tab has been completely 
removed, battery polarity is correct and the 
battery terminals are making contact with the 
smoke alarm contacts in the battery drawer. If 
chirp continues, replace the 9V battery (see 
User’s Manual for recommended battery 
types). 
3 Chirps approx. 
every 20 seconds 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off 
Off 
Condition: Sensor Trouble/Sensor End-of-
Life Alarm. 
Recommendation: Reset the alarm. If this 
does not clear the problem, replace alarm. 
2 Chirps approx. 
every 20 seconds 
On and Blinks 
Off approx. 
every 20 
seconds 
Off 
Off 
Off 
Condition: Product End-of-Service Life 
Notification. 
Recommendation: Replace the alarm 
immediately. The product end-of-service life 
notification can be temporarily silenced for a 
10 hour period for up to 20 days. After 20 
days, the warning cannot be silenced. The 
alarm should be replaced immediately. 
RESET INSTRUCTIONS: Press the Test/Silence button for 10 seconds, or until the blue LED turns on, and then release. This will clear the 
alarm latching LED’s and clear the alarm origination. Be sure to RESET alarms after each alarm event. 
 
QUICK FIND®  Alarm Origination/Location Feature: The QUICK FIND® feature will allow  you to immediately locate the  originating alarm 
(the alarm that triggered the other alarms), once the alarms have stopped sounding. 
1. Press  and  release  the  Test/Silence  button  on  any  alarm.  After  releasing  the  button,  the  test  sequence  on  this  alarm  will  begin,  and  last 
approximately 5-20 seconds. 
2. Once  this  test  sequence  ends,  the  originating  alarm  continues  to  sound  for  approximately  50  seconds,  which  provides  ample  time  to 
locate the originating alarm. 
3. Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation. 
 
NOTE:
  If  you  have  any  additional  questions  about  the  operation  of  Model  MICN109  or  MICN109L,  please  contact  our  Customer  Service 
Department at 1-800-390-4321, and we will gladly assist you. 
 
*  During 120 volt operation On and Blinks Off approx. every 20 seconds. 
   During 9 volt (DC backup) operation, Blinks On approx. every 40 seconds. 
 
 