Rear Panel 
 
Figure 1-3: Rear Panel 
 
AC 100V ~ 240V  
Connects to AC100~240V / 50~60Hz with supplied AC power cord. 
 
 
Default Settings 
When the MULTI-WAN GATEWAY has finished booting, all configuration settings will be set to the 
factory defaults, including: 
•  IP Address set to its default value of 192.168.1.1, with a Network Mask of 255.255.255.0 
•  DHCP Server is enabled 
•  User Name: admin 
•  Password cleared (no password) 
TFTP Download 
This setting should be used only if your MULTI-WAN GATEWAY becomes unusable and you are 
attempting to restore it by upgrading the firmware. Follow this procedure: 
1.  Power-On the MULTI-WAN GATEWAY. 
2.  Use the supplied Windows utility or a TFTP client program to apply the new firmware. If using the 
supplied Windows TFTP program, the screen will look like the following example: 
 
 
Figure 1-4: Windows TFTP utility