Serial Protocols 
 
 
ROS™  v3.5 
82 
RS400 
 
Figure 52: Mirrored Bits Form 
 
Port 
Synopsis: 1 to 4 
Default: 1 
The port number as seen on the front plate silkscreen of the switch. 
Transport 
Synopsis: { TCP, UDP } 
Default: UDP 
The network transport used to transport protocol data over IP network. 
Loc Port 
Synopsis: 1024 to 65535 
Default: 61001 
The local IP port to use when listening for an incoming connection or UDP data. 
Rem Port 
Synopsis: 1 to 65535 
Default: 61000 
The remote TCP port to use when placing an outgoing connection. 
IP Address 
Synopsis: ###.###.###.###  where ### ranges from 0 to 255 or { <EMTY STRING> } 
Default:  
For outgoing TCP connection (client) and UDP transport this is the remote IP address to 
communicate with. 
For incoming TCP connection (server), this is the local interface IP address to listen to the local 
port for connection request. If empti string is configured, IP address of management interface is 
used.