RuggedCom Welder RS400 用户手册

下载
页码 275
Serial Protocols 
 
 
ROS™  v3.5 
86 
RS400 
 
Protocol 
Synopsis: { TIN } 
The serial protocol supported on this serial port. 
Address 
Synopsis: Any 31 characters 
The remote device address. 
Location 
Synopsis: ###.###.###.###  where ### ranges from 0 to 255 
The IP Address of the remote host. 
IP Port 
Synopsis: 1 to 65535 
The remote port number through which remote device sent a UDP datagram or TCP connection 
is established. 
RSSI 
Synopsis: -128 to 0  or { N/A } 
The signal strength indicator received from wayside data radio. N/A for TIN Mode 1. 
Aging Time 
Synopsis: 0 to 1000 
The amount of time since the last packet arrived from the device. Once this time exceeds the 
Aging Timer setting for protocol, the device will be removed from the table. This value is 
updated every 10 seconds. 
2.3.12 Links Statistics 
This table presents detailed statistics for a specific link between two devices. 
 
Figure 57: Links Statistics Table