Powering On the Controller
This wiring - with the wire loop uncut - assumes that the R/C radio will be powered by the 
AX500 controller. Other wiring options are described in “R/C Operation” on page 81 of the 
User’s Manual.
Important Warning
Do not connect a battery to the radio when the wire loop is uncut. The RC battery 
voltage will flow directly into the controller and cause permanent damage if its volt-
age is higher than 5.5V.
Connecting the optional channel 3 will enable you to turn on and off the accessory output. 
See “Connecting Sensors and Actuators to Input/Outputs” on page 47 an“Data Logging 
in R/C Mode” on page 91 
of the User’s Manual.
Powering On the Controller
Important reminder: There is no On-Off switch on the controller. You must insert a switch 
on the controller’s power terminal as described in section“Connecting to the Batteries and 
Motors” on page 15.
To power the controller, center the joystick and trims on the R/C transmitter. In Analog 
mode, center the command potentiomenter or joystick.Then turn on the switch that you 
have placed on the on the VCon wire.
8
9
15
Pin 1
Channel 1
Wire loop bringing power from 
controller to RC radio
Channel 2
3: 
Channel 1 Command Pulses
4: 
Channel 2 Command Pulses
6: 
Radio battery (-) Ground
7: Radio 
battery 
(+)
8: 
Channel 3 Command Pulses
Channel 3
FIGURE 4. R/C connector wiring for 3 channels and battery elimination (BEC)