RGB Spectrum Quadra 用户手册

下载
页码 132
I N S T A L L A T I O N   A N D   S E T U P
System Timing
350-7951
Quadra User’s Guide
22
. .
 . 
.
6. 
Turn on the display monitor that is connected to the selected output 
channel.
7. 
Turn on the controlling device (such as your PC), allowing time for it 
to boot up. 
8. 
From the PC, establish a serial (or Telnet) connection to Quadra 
(depending upon your configuration).  If required, refer to the “
” section for instructions.
9. 
With communications properly established, turn on the “Grid” test 
pattern for the selected output channel.  Type:  
TP <output #> GRID
 and press 
Enter
.  Verify that the grid signal is visible on your 
display.  At this point, however, it may fit properly.
10. 
Using the Output Timing Load function, enter the ID of the timing 
parameters that you selected in step 3.  Type: 
OPTMLOAD <output #> <1 ... 160> 
Enter
11. 
Adjust the display to match Quadra’s output:  Note:
~
For a single display, leave the display’s “auto-sync” circuitry 
on.  Use the display’s position and size controls to center the 
test pattern, and ensure that the entire test pattern is 
completely visible.
~
In some special applications, you may choose to change 
Quadra’s output parameters rather than adjust the display 
device.  In this case, use Quadra’s Output Timing 
Interactive 
procedure to match the display settings.  Refer to 
the “
” section for details. 
12. 
Turn off the test pattern.  Type:
TP <output #> OFF 
Enter
13. 
With the display adjusted, you can now adjust Quadra’s input timing 
using the Input Interactive procedure.  Refer to the “
section for instructions. 
ADVANCED OUTPUT
. . . . . . . . . 
TIMING
For most applications and timings, the steps outlined in the previous section are 
adequate for matching Quadra’s output to your display.  However, for greater 
accuracy (particularly with dual or multi-monitor configurations), you can fine-
tune output settings using the Output Timing Interactive function.  
The “interactive” mode places a cursor on screen that defines the boundaries of 
the output signal (also known as the “active picture”).  Unlike other Quadra 
commands, the interactive mode is one that waits for keystrokes to position the 
picture, while all other commands are locked out.  
Note
The Output Timing Interactive procedure can also be 
used to “fine tune” a single display.