34
6.5.
Repeater Setup
Each NL6000 unit may have up to eight repeater entries. Each repeater
entry includes a trigger, trigger ID, transmit channel, and transmit delay
value. If a unit does not act as a repeater, do not set up any repeater
entries. For more information about setting up a repeater unit, refer to
Section 5.5
Table 3 shows how to set up the
Trigger
and
ID
values for each type of
repeater trigger.
Trigger
Field
ID Value
Use
MYID 
nnnn  
(hex)
Used to repeat a packet from a remote  to a base
station.  The ID value is the MYID of the remote,  or
group  of  remotes  if  using  a  wildcard.
TOID 
nnnn 
(hex)
Used to repeat a packet from a base station to one or
more remotes. The ID value is the TOID of the  remote,
or  group  of  remotes  if  using  a  wildcard.
Table 3: Setup of Repeater Trigger Fields
Selecting the Repeater Entry to Edit
1.
Select Network
ä Repeater ä Select Repeater Entry.
2.
Enter the number assigned to the repeater entry you want to set or edit.
Repeater entries are assigned a number in the range 1
8. After you
select an entry number, the system displays the current parameter
settings for that repeater entry.
3.
Press ESC to return to the Repeater menu where you can set any of the
four repeater parameters.
Setting the Repeater Trigger
1.
Select Network
ä Repeaterä Trigger.
2.
Select from the following options:
1-MYID
Trigger the repeater function for packets addressed with a
MYID equal to the ID value. Set the trigger ID to the MYID
of the remote unit from which you want to repeat  packets.
Refer to Table 3.
2-TOID
Trigger the repeater function for packets addressed with a
TOID equal to the trigger ID value. Set the trigger ID to the
TOID of the destination unit. Refer to Table 3.