FPI U31-2 Gas Fireplace Insert
Top View of pilot fl ame
Correct fl ame pattern has two strong blue 
fl ames: 1 fl owing around the thermopile and 
1 reaching towards the rear burner (it does 
not have to be touching the burner).
Top View of pilot fl ame
Incorrect fl ame pattern will have small, prob-
ably yellow fl ames, not coming into proper 
contact with the rear burner or thermopile.
MAINTENANCE 
INSTRUCTIONS
1)  Always turn the gas valve to off before 
cleaning. For relighting, refer to lighting 
instructions. Keep the burner and control 
compartment clean by brushing and vacu-
uming at least once a year.
 
When cleaning the logs, use a clean soft 
paint brush as the logs are fragile and easily 
damaged.
2)  Clean (never when unit is hot) appliance, 
door and louvers with a damp cloth.  Never 
use an abrasive cleaner. The gold louvers 
(and optional gold door) may be scratched 
if abrasives are used to clean them.
 
The heater is fi nished in a heat resistant 
paint and should only be refi nished with 
heat resistant paint (not with wall paint). 
FPI uses StoveBrite Paint - Metallic Black 
#6309.
3)  Make a  periodic check of burner for proper 
position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call a qualifi ed service 
person. 
4)  The appliance and venting system must be 
inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed. 
 
During the annual service call, the burners 
should be removed from the burner tray 
and cleaned. Replace the embers but do 
not block the pilot.
MAINTENANCE
WARNING:  CHILDREN AND 
ADULTS SHOULD BE ALERTED 
TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURE AND 
SHOULD STAY AWAY TO AVOID 
BURNS OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD BE 
CAREFULLY SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM 
AS THE APPLIANCE.
CAUTION:  ANY SAFETY SCREEN 
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE 
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE.
GOLD-PLATED TRIM
The 24 carat gold plated fi nish on the trim 
requires little maintenance, and need only be 
cleaned with a damp cloth. DO NOT use abrasive 
materials or chemical cleaners, as they may 
harm the fi nish and void the warranty.
 Clean any fi ngerprints off  before turning the 
unit on.   If the top louvers start to discolour, 
check the door gasket seal and replace if 
necessary.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door to carefully remove the 
logs. The pilot light generates enough heat to 
burn someone. If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagram under Log 
Installation.  
NOTE:  Improper positioning of logs may 
create carbon build-up and will alter 
the unit’s performance which is not 
covered under warranty.
GLASS GASKET
 
If the glass gasket requires replacement use 
7/8" fl at glass gasket (Part # 936-243) for the 
Bay Front and for the Flush Front.
are temperature changes within the unit these 
sounds will likely re-occur. Again, this is normal 
for steel fi reboxes.
Blower Thermodisc: 
When this thermally activated switch turns ON 
it will create a small "clicking" sound. This is the 
switch contacts closing and is normal.
Pilot Flame: 
While the pilot fl ame is on it can make a very 
slight "whisper" sound.
Gas Control Valve: 
As the gas control valve turns ON and OFF, a 
dull clicking sound may be audible, this is normal 
operation of a gas regulator or valve.
Unit Body/Firebox: 
Different types and thicknesses of steel will 
expand and contract at different rates resulting 
in some "cracking" and "ticking" sounds will be 
heard throughout the cycling process.
5)  Keep the area near the appliance clear and 
free from combustible materials, gasoline 
and other fl ammable vapours and liquids.
6)  Each time the appliance is lit, it may cause 
condensation and fog the glass.  This 
condensation and fog is normal and will 
disappear in a few minutes as the glass 
heats up.
 
Never operate the appliance without the 
glass properly secured in place, with 
broken glass or with the door open.
7)  Verify proper operation after servicing.
8)   Periodically check the pilot fl ames, there 
should be three strong blue fl ames approx. 
3/4" long - 1 fl ame to the front burner, and 
1 to the thermopile and one to the left. See 
diagrams below.
 
If you have an incorrect fl ame pattern, 
contact your FPI dealer for further instruc-
tions.