OPERATION
DAILY CLEANING:
After each period of daily operation (more frequently as 
required to maintain cleanliness) the cooker should be 
thoroughly cleaned by completing the following steps:
Remove the baffle, and left and right side pan sup-
port racks by lifting them up off their mounting brack-
ets.
Remove the drain screen by lifting it off its mounting 
studs.
Wash cooking compartment interior using detergent 
and water.  Rinse and dry thoroughly.
Remove the drip/spill trough.
Wash all removed pieces with a detergent, using a 
brush,  and  rinse.    These  pieces  can  also  be  sent 
through a commercial automatic dish washing ma-
chine. Set these pieces aside for reassembly.
Replace the drip/spill trough.
Replace the drain screen inside the cavity.
Replace baffle, and pan supports into cooking cavity 
by hanging them on their mounting brackets.
Leave door slightly ajar.
PROLONGED SHUT-DOWN & CLEANING:
This  section  includes  instructions  for  prolonged  shut-
down of the Steam Tech™ pressureless steam cooker.
Press the power switch into the “off” position. The 
steam generator will automatically drain.
Clean the cooking compartment, as described in the 
daily cleaning section above.
The Steam Generator must be rinsed and drained.  
Refer to the generator cleaning below for complete 
instructions.
CAUTION:
Disconnect the power supply to the steam generator 
before servicing.
Contact the Factory, the Factory Representative, or a 
Factory Authorized Service Company to perform main-
tenance repairs.
Keep this manual for daily reference.
GENERATOR CLEANING:
The Steam-Tech is designed with an advanced cleaning 
system which notifies the user that the steam genera-
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
3.
tor needs to be cleaned.  Your steamer permits you to 
quickly clean the generator.  The cleaning sequence is 
as follows:
The red “CLEAN” light illuminates when scale builds-
up in the tank and on the heating element
When the unit is to be used the unit must be cleaned, 
as follows.
Turn the power switch to the off position
Turn off the water supply from its source
Turn power switch on
Red light is “on” and the generator will not fill with 
water.
Locate the reset switch on the control panel depress 
it, and the red light should turn off.
Remove the cleaning solution inlet cap located on 
the right hand side of the upper brow.
Using a kitchen funnel, pour Market Forge’s TOTAL 
CONCEPT de-liming solution (P/N 20-0318) into the 
generator (2 quarts). 
Add 5 quarts of water to fill the generator to 3/4. The 
heater relay will click on.    
 
 
 
 
 
 
 
 
 
CAUTION:   
 
 
 
 
Read  directions  and  information  on  TOTAL  CON-
CEPT de-liming solution container before using. 
 
 
 
 
 
Allow  the  unit  to  preheat  until  the  green  “READY”  
light comes on.
After the ready light is on, set the timer for about 20 
minutes.
When  the  timer  has  counted  to  zero  the  system 
needs to be rinsed which is accomplished by:
 
 Turning the power OFF (the unit drains).
 
 Turn the water supply on at its source.
 
 Turning ON the power permitting water to 
 
    enter the generator.
 
 Allowing the unit to reach preheat conditions  
 
    (green light on).
 
 Setting timer for 10 minutes.
 
 Draining the rinse water after the buzzer  
 
    sounds by turning OFF the power.
After rinse water is drained, turn the power on, wait for 
the steam ready light, and you are ready to cook.  If the 
clean light comes back on the cleaning procedure must 
be followed again.