Administering the Switch for CMS High Availability Systems
 
CentreVu CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Administering the Definity Switch
4-13
Field
Definition
Network regions are 
interconnected
Enter 
n
. This application is not used for 
C-LAN.
Enabled
Enter
 y 
to enable the C-LAN IP interface. 
After initial administration, you must disable 
the interface before you make any changes.
Type
Enter
 C-LAN
.
Slot
Enter the equipment location of the C-LAN 
circuit pack. 
Code/Sfx
This is a display-only field that shows the 
designation number of the circuit pack 
installed in the specified slot.
Node Name
Enter the switch node name assigned on 
Pages 2 through 6 of the Node Names form. 
In this example, enter
 switchhost
. The 
same node name cannot be assigned to two 
different IP interfaces.
Subnet Mask
Identifies which portion of an IP address is a 
network address and which is a host 
identifier. Use the default entry, or check with 
the LAN administrator on site if connecting 
through the customer’s LAN.
Gateway Address
If the application goes to points off the 
subnet, a Gateway Address of the router is 
required; if the switch and the CMS server 
are on the same subnet, a Gateway address 
if not required. 
If required, enter the address of a network 
node that will serve as the default gateway 
for the IP interface.  If using ethernet only, 
and a Gateway Address is administered, no 
IP routes are required.
Net Rgn
For a C-LAN IP interface, use
 1
.