FIC A360 用户手册

下载
页码 187
 
Troubleshooting and Repair 
Table 6-3 (c) 
BIOS Beep Codes 
Beep 
Code 
Diagnostic 
Code 
Description Test 
Performed 
3-3-4 2Bh 
Screen memory test in 
progress or failure. 
The video buffers (B0000h and B8000h) 
are tested with a pattern test and a 
rolling ones test. Failure will result in a 
beep code but not a system halt. 
3-4-1 2Ch 
Screen initialization in 
progress. 
Until the video installation is confirmed, 
any calls to INT 10h Function 0 (set 
mode) will be prefaced with the 
diagnostic code. There is no expected 
failure from this. 
3-4-2 2Dh 
Screen retrace test in 
progress or failure. 
Over a period of time, the retrace bit 
(bit0) in the appropriate CRT controller 
status register (either port 3BAh or 
3DAh) is read and tested. The retrace bit 
should toggle from 0 to 1, then 1 to 0 
within the time period. 
None 2Eh Search for video ROM in 
progress. 
No specific test is performed by the 
system BIOS - just indicates that the 
BIOS is about to jump to the initialization 
code in the video option ROM. 
none 30h 
Screen running with video 
ROM. 
No specific test is performed  - just 
indicates that a video option ROM was 
found and believed to be operating. 
none 31h 
Monochrome monitor 
operable. 
No specific test is performed  - just 
indicates that the BIOS believes a 
monochrome monitor is installed and is 
operating. 
none 32h 
Color monitor (40-column) 
operable. 
No specific test is performed  - just 
indicates that the BIOS believes a color 
monitor is installed and is operating. The 
mode has been set to 40-column as 
selected by the user in CMOS RAM. 
none 33h 
Color monitor (80-column) 
operable. 
No specific test is performed - just 
indicates that the BIOS believes a color 
monitor is installed and is operating. The 
mode has been set to 80-column as 
selected by the user in CMOS RAM. 
4-2-1 34h 
Timer-tick interrupt test in 
progress or failure. 
All interrupts expect the timer-tick 
interrupt are masked off at the interrupt 
controllers. If a timer-tick interrupt does 
not occur during a specific time period, 
an error message is displayed on the 
screen. The system does not halt. 
4-2-2 35h 
Shutdown test in progress or 
failure. 
A return address is stored in 40:67h and 
the processor is reset via the keyboard 
controller. If a timer tick occurs during 
this time period, an error message is 
displayed on the screen. Other failures 
are hard to detect. If possible, the BIOS 
will continue with POST, skipping the 
memory tests. 
 
FIC A360 Service Manual 6-7