Chapter 4: Installation
4-6
SEHI100TX User’s Guide
3. Ensure that the rack used will support the unit, and that the rack will 
remain stable with the unit installed in it. Support the SEHI securely 
from underneath, and align the mounting brackets of the SEHI chassis 
with the screw holes in the equipment rack as shown in Figure 4-5. 
Fasten the SEHI to the equipment rack securely.
Figure 4-5
Installing the SEHI in the Rack
!
CAUTION
The cooling fans at the rear panel of the SEHI must have 
adequate clearance (two inches on either side and in the 
rear
) for unrestricted air flow. The temperature for the selected 
location must be maintained between 5
°
C and 40
°
C, and 
fluctuate less than 10
°
C per hour.