Apex 1 to 5.5 kW Generator
201
report unit 
on events
Reports a count of unit on events
Note: The response contains 4 bytes which 
represent a 32-bit count of events (LSB 
first).
4 data bytes
32-bit value
202
report 
output on 
events
Reports a count of output on events
Note: The response contains 4 bytes which 
represent a 32-bit count of events (LSB 
first).
4 data bytes
32-bit value
203
report 
overtemp 
events
Reports a count of overtemp events
Note: The response contains 4 bytes which 
represent a 32-bit count of events (LSB 
first).
4 bytes
32 bit value
205
read run 
time
Requests the amount of time (in seconds) that 
the generator was producing output.
Note: The response contains 4 bytes which 
represent a 32-bit time (LSB first). It 
returns the amount of time in seconds 
that the unit was producing output.
4 data bytes
32-bit value
206
read total 
energy 
output
Requests the total amount of energy (in kWh) 
delivered by the generator.
Note: The response contains 4 bytes which 
represent a 32-bit time (LSB first). It 
returns the amount of energy in kilo 
watt hours delivered by the unit.
4 data bytes
32-bit value
210
report fault 
warnings 
and 
shutdowns
Returns faults, warnings, and shutdowns
Note: The response contains 1 data byte 
which represents fault warnings and 
shutdowns.
bit 0 indicates ripple warning 
(0 = inactive, 1 = active)
bit 1 indicates ripple failure 
(0 = inactive, 1 = active)
bit 2 indicates temperature rate failure 
(0 = inactive, 1= active)
1 data byte
8-bit value
Table 4-6. Host Port Commands for RS-232 with AE Bus  (Continued)
Command
Description
Number of 
Host Data 
Bytes
Number of 
Response 
Data Bytes