Apex 1 to 5.5 kW Generator
AE PROFIBUS PROTOCOL
Profibus (Process Field Bus) is an interface that lets you communicate with your Apex 
generator from a host (master). AE manufactures a certified Profibus, which means 
the interface is tested and certified to work with Profibus masters described in the DIN 
19245 Profibus Standard DP, part III. Any Profibus master that complies with this 
standard can communicate with AE’s certified Profibus. 
Note: Before controlling/monitoring the Apex generator through the host port, you 
need to ensure that the required User port inputs are satisfied and that the 
control mode is properly set. The required User port inputs are identified under 
the Satisfying Minimal Requirements section for your User port. To determine 
which User port you have, see the PIN position 8 in Table 1-1. on page 1-4. The 
control mode is usually set to the PROFIBUS as default when this host port 
option is installed. To ensure the control mode is set to host, see commands 14 
(sets control mode) and 155 (reads control mode) in the “Profibus Command 
Set” on page 4-66. 
The Profibus Host port on the generator is a 9-pin, female, subminiature-D connector 
and an eight-switch DIP located beneath the connector, which is used to set the Apex 
generator’s network address (see “Setting the Network Address with the Profibus DIP 
Switch” on page 4-60)
Figure 4-8. Host port connector with Profibus
Note: AE’s Profibus protocol does not support the following functions: address 
changing, freeze/unfreeze modes, or sync modes.
Table 4-7 describes the Profibus Host port pins.
Table 4-7. Profibus Host Port Pins
Signal 
Pin
Name
Description
1
UNASSIGNED
2
UNASSIGNED
3
A
Data bus A