PROFIBUS COMMAND SET
Table 4-11 lists the command set for the Profibus Host port.
Table 4-11. Profibus Host Port Commands
Command
Description
Number of 
Transmit 
Data Bytes
Number of 
Response 
Data Bytes
1
RF off
Requests RF output off; request is always 
honored regardless of which interface has 
control. (Readback command is 162.) 
0
2
RF on
Requests RF output on; host control must 
have been selected.
0
3
regulation 
select
Sets the method of output regulation (forward 
power—6, load—7, and ext—8). (Readback 
command is 164.)
1 data byte
8-bit value
4
fwd pwr 
limit
Specifies maximum forward power that can be 
delivered; accepts a value of 0 to 8000 W (for 
the 8 kW option) or 0 to 10000 W (for the 10 
kW option). (Readback command is 169.)
2 data bytes
16-bit value
5
refl pwr 
limit
Specifies maximum reflected power that can 
be tolerated; accepts a value of 0 to 20% of 
full rated power. (Readback command is 170.)
2 data bytes
16-bit value
6
ext feedback 
limit
Specifies the maximum external feedback 
level; accepts a value from 0 to the maximum 
external feedback value. (Readback command 
is 171.)
This command sets the value at which the 
setpoint is limited during external regulation 
2 data bytes
16-bit value
8
setpoint
Specifies the output setpoint level for 
whatever method of output regulation has 
been selected. Accepts a value of 0 to 8000 W 
(for the 8 kW option) or 0 to 10000 W (for the 
10 kW option) when forward or load power 
regulation is selected.
2 data bytes
16-bit value