Apex Digital 5708009-C 用户手册

下载
页码 160
4-70
5708009-C
Advanced Energy
®
164
read 
setpoint/
regulation 
mode
Requests output setpoint level (set by CMD 8
and whatever method of output regulation has 
been selected (set by CMD 3). The return 
packet is arranged as follows:
First and second bytes = setpoint value.
Third byte = method of output regulation.
0
3 data bytes
16-bit value
8-bit value
165
read 
forward 
power
Requests a snapshot of forward power level at 
that instant.
0
2 data bytes
16-bit value
166
read 
reflected 
power
Requests a snapshot of reflected power level 
at that instant.
0
2 data bytes
16-bit value
167
read 
delivered 
power
Requests a snapshot of load power level at 
that instant.
0
2 data bytes
16-bit value
168
read ext 
feedback (dc 
bias)
Requests a snapshot of external feedback level 
at that instant.
0
2 data bytes
16-bit value
169
read fwd 
pwr limit
Requests programmed limit for forward power 
(set by CMD 4).
0
2 data bytes
16-bit value
170
read refl 
pwr limit
Requests reflected power limit (set by 
CMD 5).
0
2 data bytes
16-bit value
171
read ext 
feedback 
limit
Requests external feedback limit (set by 
CMD 6).
0
2 data bytes
16-bit value
184
read out-of-
setpoint 
interval
Requests how long the generator is 
programmed to produce output that is not 
equal to the programmed setpoint level before 
shutting output off (set with CMD 15).
0
2 data bytes
16-bit value
Table 4-11. Profibus Host Port Commands (Continued)
Command
Description
Number of 
Transmit 
Data Bytes
Number of 
Response 
Data Bytes