Output protection—Apex generators sense and employ several parameters for protection
Reflected power limit
20% of maximum forward power for units rated for less 
than 5500 W. 1000 W for 5500 W units. (PIN position 2 
defines the maximum forward power rating for the unit.)
Dissipation limit
Maximum PA dissipation—non-latching alarm LED
Low/high line bus
Bus voltage outside spec window—latching alarm LED
Over-temperature
Over-temp condition—latching alarm LED preceded by 
non-fault warning (user setting).
Output power range
All generators except the HALO will allow setpoints 
between 1% and 100% of full scale. The exception is the 
HALO 1.5k generator depicted by “L” in position 2 of the 
PIN number. This allows setpoints from 5 watts to 1500 
watts.
Output power regulation accuracy
Into 50 
Ω non-reactive load
± 1% of setpoint or ± 0.1% of full-rated output, 
whichever is greater (all PIN position 2 options but K 
and L)
≤ ±1% of setpoint or 0.25 W, whichever is greater 
(PIN position 2, option K & L)
Into 3:1 VSWR non-
reactive load
± 3% of setpoint (load power regulation), over all load 
phase angles, or ± 0.25% of full-rated output, which ever is 
greater
Load regulation as a function 
of line regulation
Less than 0.1% change in output power for 10% change in 
ac line voltage
Load regulation as a function of temperature—(performance in accordance with the output 
power regulation accuracy)
Ambient air temperature 
range
+5
°
C to +40
°
C
Cooling water temperature 
range
+5
°
C to +35
°
C
Spurious outputs—Referenced to fundamental signal at full-rated output when operated in a 
50 
Ω non-reactive load
Harmonic related
-40 dBc
Non-harmonic related
-50 dBc
Table 3-3. Output Specifications (Continued)
Description
PIN Option and Specification