Apex Digital 5708009-C 用户手册

下载
页码 160
5708009-C
4-29
Apex 1 to 5.5 kW Generator
4
RF POWER ENABLE
Digital 
input
This pin represents RF 
output being enabled 
when a 4 to 30V input (pin 
9, RF ON BIAS, can be 
used as a voltage source) 
is present on this pin.
Note: The interlocks must 
be satisfied and the 
setpoint must be 
within the Output 
power range before 
unit will deliver 
power. See Table 3-
3. on page 3-6 f
or 
the Output power 
range specification.
5
6
FORWARD / LOAD 
POWER SETPOINT
Analog 
input
This analog signal 
provides a linearly scaled 
control of the forward or 
load output power 
depending on the 
regulation mode.
0 to 10V = 0 to maximum 
rated power output as 
defined by configuration 
PIN in Table 1-1 position 
2.
Note: The interlocks must 
be satisfied and the 
setpoint must be 
within the Output 
power range before 
unit will deliver 
power. See Table 3-
3. on page 3-6 f
or 
the Output power 
range specification.
Table 4-3. User Port (15-pin) Connector Pins Exclusive for Configuration E (Continued)
Signal 
Pin
Return 
Pin
Name
Signal 
Type
 Description