Alvarion BREEZENET BU-DS.11 用户手册

下载
页码 92
Installation 
 
 
 
2-13 
Installing the Indoor Unit 
Route the indoor-to-outdoor cable into the building so that it conveniently reaches 
the indoor unit while avoiding interference sources. It is recommended that the 
cable be a little longer then necessary. The cable is supplied open ended so it can 
be conveniently threaded as shown into the building.  
1. 
The unit can be placed on a desktop or a shelf. Alternatively, it may be wall-
mounted. The drilling template included with the unit can be used to simplify 
the wall installation process. 
2. 
Assemble an RJ-45 connector with a protective cover on the indoor side of the 
indoor-to-outdoor cable. Refer to Appendix B for instructions on preparing the 
RJ-45 cable connector. 
3. 
Connect the indoor-to-outdoor cable to the Radio connector, located on the top 
2-6. The indoor-to-outdoor cable 
should be connected to the unit before the unit is connected to the mains 
power. 
4. 
After connecting the outdoor unit to the indoor unit using the indoor-to-
outdoor cable, connect the power cord to the unit’s AC socket, located on the 
bottom panel. Connect the other end of the power cord to the AC mains after 
verifying that the unit is rated for the voltage in the country of use; the AC 
rating is indicated on the bottom panel of the indoor unit. 
 
NOTE: 
The color codes of the power cable are: 
Brown: phase ~ 
Blue: neutral 0 
Yellow/Green: grounding   
 
5. 
Verify that the yellow POWER LED located on the top panel is lit, indicating 
that the unit is supplying power to the radio port. 
 
Figure 
 
2-6: Indoor Unit Top Panel