   Allen & Heath                                                            22                                               ZED-R16 User Guide 
MASTER SECTION 
Control Room Monitor jack sockets 
Standard 1/4” (6.25mm) Jack socket for connecting powered monitor 
speakers  or  an  amplifier  for  the  engineers  control  room  monitor 
speakers.  Impedance  balanced.  Wired  Tip=Hot(+),    Ring=cold  (-), 
Sleeve=Chassis.
 
CRM L
CRM R
ALT L
ALT R
2 TRACK 1 IN
L
R
2 TRACK 2 IN
L
R
L
+16
-6
-9
-20
-30
-16
-12
-3
0
+3
+6
+9
R
+16
-6
-9
-20
-30
-16
-12
-3
0
+3
+6
+9
PFL/AFL ACTIVE
2 TRACK DUB
2 TO 1
1 TO 2
TALK
LEV
TALK
TO STUDIO
TO AUX 1 & 2
MIN
MAX
POWER
2 TRACK 1
REPLACE L-R
Alternate Monitor jack sockets 
Standard 1/4” (6.25mm) Jack socket for connecting powered monitor 
speakers or an amplifier for an alternative set of speakers to the main 
CRM speakers. Typically these would be nearfield monitors or speak-
ers in close proximity to the engineer.  
Impedance  balanced.  Wired  Tip=Hot(+),    Ring=cold  (-), 
Sleeve=Chassis. 
2 Track 1 Input phono sockets 
Standard  RCA  phono  sockets  for  unbalanced  stereo  sources.  Useful 
for  connecting  equipment  with  stereo  analogue  outputs  such  as  CD 
players  and  DAT  machines  for  playing  backing  music,  copying  from 
one machine to another or simply listening to that machine. 
2 Track 2 Input jack sockets 
Standard 1/4” (6.25mm) Jack socket for connecting balanced or unbal-
anced  stereo  sources.  The  2  Track  2  inputs  are  available  to  be 
switched to the 2 Track 1 (main xlr) outputs for dubbing or copying 
purposes. 
Main meters 
The main stereo 12 segment peak response slow decay meters are fed 
with the control room monitor signal (pre CRM Level). The selection 
switches  for  the  CRM  source  are  located  below  the  Phones  Level 
control and is over-ridden by the PFL or AFL signal if any listen switch 
is pressed. 
PFL/AFL Active LED 
Illuminates  when  any  PFL  or  AFL  switch  is  pressed.  It  indicates  that 
the  meters  will  show  the  PFL  or  AFL  signal,  or  the  mix  of  signals  if 
more than one switch is pressed. 
2 TRACK DUB switches 
Allow dubbing or copying from one stereo source to another.  
If 2 to 1 is pressed then 2 Track 2 input jack sockets will be routed to 
the 2 Track 1 output xlr’s. 
If 1 to 2 is pressed then 2 Track 1 input phono inputs will be routed 
to the 2 Track 2 output jacks. 
2 TRACK 1 replace L-R switch 
If this switch is pressed the main L-R mix is replaced by the 2 Track 1 
input. The switch is situated before the insert points in the signal path, 
so  any  inserted  processing  will  still  have  effect,  as  will  the  main  L-R 
faders.