Mains Power and Earthing 
Connecting Mains Power
   Read the SAFETY INSTRUCTIONS  printed at the front of this 
user guide and on the rear panel.  The power supply is a high performance switched mode type with 
universal mains input to accept voltages from 100 to 240 V.AC.  Check that the correct mains lead with 
moulded plug has been supplied with your console.  Ensure that the IEC mains plug is pressed fully 
into the rear panel socket before switching on. 
 
 To avoid any unexpected audible clicks or thumps turn connected power amplifiers down 
or off before switching the console or any other signal equipment on or off.  
Switching On   Press the rear panel ON/OFF switch in.  The front panel blue power LED lights.  The 
meters and several other LED indicators may pulse briefly.  This is quite normal. 
Switching Off   Check that the system amplifiers are turned down or off.   Release the rear panel 
ON/OFF switch. 
 
Earthing
   The connection to earth (ground) in an audio system is important for two reasons: 
SAFETY to protect the operator from high voltage electric shock, and AUDIO PERFORMANCE to shield 
the audio from interference. 
For safety it is important that all equipment earths are connected to mains earth so that exposed metal 
parts are prevented from carrying high voltage which can injure or even kill the operator.  It is 
recommended that the system engineer check the continuity of the safety earth from all points in the 
system including microphone and instrument metal, equipment cases, rack frames, and so on. 
The same earth is also used to shield audio cables from external interference such as the hum fields 
associated with power transformers, lighting dimmer buzz, and computer  radiation.    Problems  arise 
when the signal sees more than one path to mains earth.  An ‘earth loop’ (ground loop) results causing 
current to flow between the different earth paths.  This condition is usually detected as a mains 
frequency audible hum or buzz.  To ensure safe and trouble-free operation we recommend the 
following: 
 
Have your mains system checked by a qualified electrician    If  the  supply  earthing  is  solid  to 
start with you are less likely to experience problems. 
 
Do not remove the earth connection from the console mains plug  The console chassis is 
connected to mains earth through the power cable to ensure your safety.  Audio 0V is connected to 
the console chassis internally. 
 
Deal with ground loops   Should you experience hum or buzz caused by earth loops, check first 
that each piece of equipment has its own separate path to earth.  If so, operate earth lift switches 
on connected equipment in accordance with the instruction manuals.  Alternatively, disconnect the 
cable screen at the destination end only.  This breaks the offending loop while still maintaining the 
signal shielding down the length of the cable. 
 
Use low impedance sources such as microphones and line level equipment rated at 200 ohms or 
less to reduce susceptibility to interference.  For high impedance instruments use DI (direct inject) 
boxes such as those readily available from most music equipment suppliers.  The console outputs 
are designed to operate at very low impedance to minimise interference problems. 
 
Use balanced connections for the microphone inputs and main outputs as these provide 
further immunity by cancelling out interference that may be picked up on long cable runs.  Refer to 
the cable diagrams for details on how to connect balanced and unbalanced equipment. 
 
Route cables to avoid interference   To avoid interference pickup keep audio cables away from 
mains power units and cables, thyristor dimmer units or computer equipment.  Where this cannot 
be avoided, cross the cables at right angles to minimise interference. 
 
Use good quality cables and connectors and check for correct wiring and reliable solder joints.  
Use the correct cable type.  Allow sufficient cable loop to prevent damage through stretching.  
If you are not sure ... Contact your service agent or local Allen & Heath dealer for advice. 
CAUTION
100 - 240 V AC  ~  47- 63 Hz
ATTENTION:  REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
CAUTION:   FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
100-240V  T1A L
ON/OFF
I
0
75W MAX
FUSE
REPLACE FUSE WITH SAME TYPE AND RATING.
DO NOT OPEN
THIS APPARATUS MUST BE EARTHED BY THE POWER CORD.
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
SEE OPERATING MANUAL BEFORE USING.
RISK OF ELECTRIC SHOCK
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
NO USER SERVICEABLE PARTS INSIDE.
WARNING:  TO REDUCE THE RISK OF ELECTRIC SHOCK
MAINS INPUT