Event / Sensor 
ALARM INPUT
Configurations for any external alarm 
device (i.e. a Door or Window Sensor). 
Refer to the appendices for hardware 
configuration details.
• Operation - Sets the Alarm Sensor 
Connection Status (Enable / Disable) 
for an external alarm (i.e. Door or 
Window Sensors).
• Type: Sets the Alarm Sensor type to 
N/O (Normally Open) or N/C (Normally 
Closed).
• N/O (Normally Open) - Select for an Alarm 
that has a Normally Open circuit (such as 
a door that remains open). An Alarm will 
occur when this is changed to a Closed 
status.
• N/C (Normally Closed) - Select for an 
Alarm that has a Normally Closed circuit 
(such as a Window Sensor). An Alarm will 
occur when this is changed to a Opened 
status.
ALARM OUTPUT
Sends an Alarm Out signal to a device 
(such as a Manual Door or independent 
Light/Buzzer Alarm) when an Alarm In 
event is detected.
Note: You must have the option, 
“Operation,” ENABLED in order to 
configure the options in this menu.
• Relay - By default, 1. Non-selectable.
• Mode - Setup Reacted Relay as either 
Latched or Transparent Mode:
• Latched – When sensor alarm activated, 
relay reacted in setup duration.
• Transparent – Relay reacted temporary 
during sensor alarm activate.
• Type - Set the Relay Type to either N/
O (Normally Open) or N/C (Normally 
Closed).
• Operation - Setup Relay Connect with 
Alarm Sensor to either Enable or 
Disable.