Delta Tau TURBO CLIPPER DRIVE 用户手册

下载
页码 87
Turbo Clipper Drive User Manual 
 
Motor Setup Guidelines 
61 
PWM Scale Factor: Ixx66 
If Motor Rated Voltage > Bus Voltage: 
I166=1.10*I7000 
 
; Motor #1 PWM Scale Factor. Set to 10% above PWM Count. 
I266=I166 I366=I166 I466=I166 ; Assuming same motor(s) as motor #1  
 
If Bus Voltage > Motor Rated Voltage: 
Ixx66 acts as a voltage limiter. In order to obtain full voltage output it is set to about 10% over 
PWM count divided by DC Bus/Motor voltage ratio: 
#define DCBusInput 
60 
; DC Bus Voltage -User Input  
 
#define Mtr1Voltage 
24 
; Motor 1 Rated Voltage [VDC]-User Input 
#define Mtr2Voltage 
24 
; Motor 2 Rated Voltage [VDC]-User Input 
#define Mtr3Voltage 
24 
; Motor 3 Rated Voltage [VDC]-User Input 
#define Mtr4Voltage 
24 
; Motor 4 Rated Voltage [VDC]-User Input 
 
I166=1.10*I7000*Mtr1Voltage/DCBusInput 
; Motor 1 PWM Scale Factor 
I266=1.10*I7000*Mtr2Voltage/DCBusInput 
; Motor 2 PWM Scale Factor 
I366=1.10*I7000*Mtr3Voltage/DCBusInput 
; Motor 3 PWM Scale Factor 
I466=1.10*I7000*Mtr4Voltage/DCBusInput 
; Motor 4 PWM Scale Factor