Copper Brute B4 Volume Water Heaters
Page 27
The following tools are required for proper 
service and problem diagnosis of the heater and 
heating system. 
1.      Gas pressure test kit with range from 0 to 14 
inches (0 to 356 mm) W.C.
2.      Electric meter(s) with the following ranges:
         a. 0 to 500 volts VAC
         b. 0 to 2000 ohms ()
         c. 0 to 20 microamps (mA)
         d. 0 to 50 millivolts (mV)
3.      A pressure gauge and a thermometer with proper 
ranges for heater operation.
5.2.1  Heater Does Not Come On 
Important: 
Disconnect power to the heater 
or pull the RED wire off the transformer secondary 
before removing or replacing any component or wire 
connection. 
 
WARNING
If power is not disconnected, jumpering gas valve 
or accidental grounding of the wire harness, or 
component terminals to the heater frame or jacket 
could cause the ignition control fuse to blow or 
may cause the heater to fire, resulting in injury or 
property damage.
1.      Make sure the heater has been properly installed.
2.      Make sure the pump is not airlocked, clogged or 
otherwise inoperative.
3.      Make sure the gas valve is on and there is gas 
pressure in the line.
4.      Check all electrical connections and wiring. 
Finding a loose connection or a charred wire can 
save a lot of time and money.
5.      Check the fuse inside the black, twist-lock fuse 
holder. If it is burned, replace it with a 2-amp 
fuse (Part No. E0084400). If there is a short, the 
cause of the short must be found and repaired. 
Do not jumper or bypass the fuse.
6.      Make sure the electrical circuit to the heater is 
on.
7.      Make sure the toggle switch on the right side of 
the heater is on.
8.      Make sure the temperature control is set high 
enough to call for heat.
9.      Make sure the manual reset on the safety controls 
(e.g., low water cutoff, hi-limit switch, etc.) has 
not tripped. If it has, reset it.
Figure 37.  Testing the transformer.
If the pump is circulating water, and the rest of 
these items check out all right, the trouble could be in 
the heater control system.
 
Caution
Label all wires prior to disconnection when servicing 
controls. Wiring errors can cause improper and 
dangerous operation. Verify proper operation after 
servicing.
5.2.2  Testing the Transformer
NOTE: Keep the pump running.
Testing the transformer requires an AC voltmeter 
with a 50 volt (V) range. Test the transformer using the 
following procedures:
1.      Clip a lead from the voltmeter to the yellow wire 
terminal on the transformer.
2.      Touch the other lead to the red wire terminal 
(see Figure 37). The voltmeter should read 24 to 
28VAC. 
3.      If the voltmeter does not show voltage, check the 
electrical power supply.
4.      If the voltage is less than 20VAC, the electrical 
circuit to the heater may be supplying less than 
103VAC. This could be due to high pump load or 
air conditioners or other appliances on the circuit.