Vent System Chart
Number of 
90° turns  
or elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
2
0
Rigid metal
Rigid metal
Rigid metal
43 ft. (13.1 m)
33 ft. (10.1 m)
24 ft. (7.3 m)
36 ft. (11.0 m)
26 ft. (7.9 m)
16 ft. (4.9 m)
The “Vent System Chart” provides venting requirements that 
will help achieve best drying performance.
NOTE: Side exhaust installations have a 90º turn inside the 
dryer. To determine maximum exhaust length, add one 90º 
turn to the chart.
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
 
Select route that will provide straightest and most direct  
path outdoors.
 
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
as possible.
 
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
Determine vent length and elbows needed for best 
drying performance:
 
Use following “Vent System Chart” to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in “Vent System Chart.” Exhaust systems longer than those 
specified will:
 
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
and increased energy usage.
INSTALL VENT SYSTEM
1. 
Install exhaust hood
12" min.
(305 mm)
12" min.
(305 mm)
2. 
Connect vent to exhaust hood
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location using 
straightest path possible. Avoid 90° turns. Use clamps to seal 
all joints. Do not use duct tape, screws, or other fastening 
devices that extend into interior of vent to secure vent, 
because they can catch lint.