GE ISOVOLT Titan E 产品宣传册
![GE](https://files.manualsbrain.com/attachments/ab9edb4caba5619c2fde3c8024ebd3386de893ab/common/fit/150/50/5e42700264754ddc6c8abde125a62fae9215a8ad130cb92d4b61e1d54d06/brand_logo.jpeg)
System layout for Exemplary Setups
Unipolar operation
Bipolar operation
legend
(1) Mains connecting cable, standard length 10 m / 32 ft, with wire
end ferrules
(2) Control Module ISOVOLT Titan E in desktop housing
(optional 19” rack house)
(3) Connecting cable control/power stage, standard length 10 m
(max. 100 m) / 32 ft. (max. approx 320 ft.)
(4a) High Voltage Generator, 160 kV or 225 kV, Cathode,
with integrated power module TiTan E
(4b) High Voltage Generator, 160 kV or 225 kV, Anode
incl. Connecting cable
(5) High Voltage Cables, 160 kV or 225 kV, standard length
5 m / 16 ft (max. 20 m / 64 ft for 160 kV - 320 kV; max. 10 m / 32 ft
for 420 kV and 450 kV)
for 420 kV and 450 kV)
Input and output connections
• RS 232 interface for connection of machine controls
• Interlock as per DIN 54113.
• Interlock as per United States Radiation Control Act of 1968,
§ 1020.40.
• Additional warning output that is active during
pre-warning time.
• External START/STOP.
• External EMERGENCY-STOP.
• Cooling system.
• External warning flash lamp (fail-safe).
• Interlock as per DIN 54113.
• Interlock as per United States Radiation Control Act of 1968,
§ 1020.40.
• Additional warning output that is active during
pre-warning time.
• External START/STOP.
• External EMERGENCY-STOP.
• Cooling system.
• External warning flash lamp (fail-safe).
(5)
(2)
(1)
(3)
(4a)
(7a)
(6a)
(8a)
(5)
(6b)
(5)
(5)
(2)
(3)
(7b)
(8b)
(1)
(4a)
(4b)
(6a) Unipolar Tube Housing
(see tube overview or separate product information)
(6b) Bipolar Tube Housing
(see tube overview or separate product information)
(7a) Water hoses, standard length 10 m (max. 20 m) / 16 ft (max. 32 ft)
(7b) Cooling Oil hoses, standard length 6m (max. 20 m) / 19 ft (max.
(7b) Cooling Oil hoses, standard length 6m (max. 20 m) / 19 ft (max.
64 ft)
(8a) Water Cooling Pump with built in flow rate monitor,
see separate specification
(8b) Oil Cooling Pump, see separate specification
• “Mains ON” (230V / 2A
2
).
• “High Voltage ON” (230V / 2A
2
).
• Potential-free contact, for “Mains ON” (60V AC / 75V DC / 2A
1
).
• Potential-free contact, for “Pre-warning Time ON”
(30V AC/36V DC / 0.5A
(30V AC/36V DC / 0.5A
1
).
• Potential-free contact, for “High Voltage ON”
(60V AC / 75V DC / 2A
(60V AC / 75V DC / 2A
1
).
1) This voltage corresponds to the max. operating voltage (rating as per VDE 0110 Group B).
2) These 230 V contacts are collectively fused with 2.5 A.
9
8