CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
 
 
 
Protocol Command 
This command changes the communication protocol of a given port. If you enter a 
protocol that blocks communication with the unit or is otherwise undesirable, and you 
have not used KEEP, you may restore the previous format by powering the unit down 
and back up. Protocol codes differ for serial and parallel models. In the parallel models 
only port 0 has a changeable protocol. In the serial models any port may be changed. 
For command syntax see TABLE 3 for serial models and TABLE 4 for parallel models. 
Keep in mind that protocol changes are made when you exit the configuration mode. 
 
Table 3. Serial Protocol Command Syntax 
Command Syntax: !@Fpabcd 
where p = Port number                             
a= Parity 
b = Flow control 
c = Data format 
d = Baud rate 
0 = none  
0=DTR/DSR 
0 = 1 stop,8 bits 
0 = reserved 
2 = odd 
8=X-on/X-off 
2 =1 Stop,7 bits 
1= 50 
6 = even                         
4 = 1 stop,6 bits 
2= 75 
A = mark                             
6 = 1 stop,5 bits 
3= 110 
E = space                          
8 = 2 stop,8 bits 
4= 134.5 
                                          
A = 2 stop,7 bits 
5= 150 
                                           
C = 2 stop,6 bits 
6= 300 
                                         
E = 1.5 stop,5 bits 
7= 600 
                                                                              
8= 1200 
                                                    
 
9= 1800 
                                                    
 
A= 2400 
                                                    
 
B= 3600 
                                                    
 
C=4800 
                                                    
 
D=7200 
                                                    
 
E= 9600 
                                                    
 
F= 19200 
Examples: 
To set port 3 to 4800 baud, 1 stop. 7 data bits, even parity, X-on/X-off the command is 
!@ F3682C 
To set port 5 to 1200 baud, 1 stop, 8 data bits, no parity, DTR/DSR the command is 
!@F50008 
 
 
Table 4. Parallel Protocol Command Syntax 
In a parallel unit only port 0 can have its protocol changed. This protocol command is 
used to support printers that do not have an acknowledge or busy signal. 
 
 Command syntax: !@F00x00 
 where x =  0 to use busy and acknowledge (Standard parallel interface) 
             
1 to use busy, ignore acknowledge 
             
2 to use acknowledge, ignore busy 
             
3 to ignore busy and acknowledge 
Example: To ignore busy the command would be:!@F00200