Rose electronic Photo CTP-8S 用户手册

下载
页码 40
OPERATIONS 
16 
CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
 
 
 
Initial State 
Following the successful completion of the power up tests, the Caretaker Plus turns all 
the port LEDs off. The BUSY LED may be lit if the shared device is busy. 
Normal Operation 
Input devices, usually computers, initiate requests to connect to the shared device by 
sending data to the Caretaker Plus. If no other ports are currently connected, connection 
with the shared device is made immediately. If other ports are currently connected, the 
requesting port must wait for all other ports ahead of it to use the shared device before it 
will be connected. An input device may send data to the unit's buffer while it is waiting to 
be connected. 
 
When data is received from the currently connected port, it is sent to the shared device if 
it is not busy; otherwise, the data is stored in the buffer until the shared device becomes 
ready. Data from a queued port is stored in the port's buffer until the port becomes 
active; at that time, the data is sent to the shared device whenever it is not busy. For 
serial models only, data that is received from the shared device is sent to the currently 
connected port if it is not busy; otherwise, the data is stored in the buffer until the port 
becomes ready. 
 
For serial models, when a port is connected to the shared device, full duplex 
communication is in effect; data can flow in either direction between the connected port 
and the shared device.  For parallel models, data can flow only in one direction, from the 
connected port to the shared device. 
 
The LED corresponding to the port currently connected to the shared device will flash 
and LEDs corresponding to ports waiting for use of the shared device will be lit steadily. 
If no data is sent to or from the currently connected port for the duration of the timeout 
setting and the shared device and the connected input device are not busy, the current 
port will be disconnected and its LED will go from the flashing state to the unlit state. The 
next port in the queue will become connected and its LED will go from the steadily lit 
state to the flashing state. Any data sent to the buffer while waiting will now be sent to 
the shared device. 
 
The timeout is reset by four possible conditions:  
1. Data is transmitted by the connected input device 
2. Data is transmitted by the shared device (if REVERSE CHANNEL DATA TIMEOUT is 
  enabled) 
3. The shared device is busy 
4. The connected input device is busy (if TIMEOUT ON BUSY is disabled). The timeout 
  period begins only when none of these conditions exist. To determine the state of the 
  unit by its LEDs see TABLE 5.